http://dbpedia.org/ontology/abstract
|
تصوير المدوارة الحرة لحالة الاضطراد هو عبارة عن تتابع للتصوير بالرنين المغناطيسي يستخدم حالة الاضطراد للمغنطة، ويعتمد على تتابع تدرج الصدى مع تقصير وقت التكرار.
, Steady-state free precession (SSFP) imagin … Steady-state free precession (SSFP) imaging is a magnetic resonance imaging (MRI) sequence which uses steady states of magnetizations. In general, SSFP MRI sequences are based on a (low flip angle) gradient echo MRI sequence with a short repetition time which in its generic form has been described as the FLASH MRI technique. While spoiled gradient-echo sequences refer to a steady state of the longitudinal magnetization only, SSFP gradient-echo sequences include transverse coherences (magnetizations) from overlapping multi-order spin echoes and stimulated echoes. This is usually accomplished by refocusing the phase-encoding gradient in each repetition interval in order to keep the phase integral (or gradient moment) constant. Fully balanced SSFP MRI sequences achieve a phase of zero by refocusing all imaging gradients. zero by refocusing all imaging gradients.
, 穩定態自由旋進造影(steady-state free precession, SSFP, imaging)利用到核磁共振中的一種特殊穩定態達成的造影方式,一般分類上屬於梯度迴訊家族。旋進亦稱為進動,因而在翻譯上,此技術可能有些不一樣的名字,中國大陆地区譯作穩態自由進動成像、定常态自由进动成像。
|
http://dbpedia.org/ontology/thumbnail
|
http://commons.wikimedia.org/wiki/Special:FilePath/Four_chamber_cardiovascular_magnetic_resonance_imaging.gif?width=300 +
|
http://dbpedia.org/ontology/wikiPageID
|
5872318
|
http://dbpedia.org/ontology/wikiPageLength
|
5881
|
http://dbpedia.org/ontology/wikiPageRevisionID
|
1123007110
|
http://dbpedia.org/ontology/wikiPageWikiLink
|
http://dbpedia.org/resource/Gradient_echo +
, http://dbpedia.org/resource/Category:Magnetic_resonance_imaging +
, http://dbpedia.org/resource/Spin_echo +
, http://dbpedia.org/resource/Free_induction_decay +
, http://dbpedia.org/resource/General_Electric +
, http://dbpedia.org/resource/Voxel +
, http://dbpedia.org/resource/FLASH_MRI +
, http://dbpedia.org/resource/Magnetic_resonance_imaging +
, http://dbpedia.org/resource/File:Four_chamber_cardiovascular_magnetic_resonance_imaging.gif +
, http://dbpedia.org/resource/Siemens_AG +
, http://dbpedia.org/resource/Magnetization +
, http://dbpedia.org/resource/Philips +
, http://dbpedia.org/resource/MRI_sequence +
, http://dbpedia.org/resource/MRI +
, http://dbpedia.org/resource/Phase_%28waves%29 +
|
http://dbpedia.org/property/wikiPageUsesTemplate
|
http://dbpedia.org/resource/Template:Anchor +
, http://dbpedia.org/resource/Template:Reflist +
|
http://purl.org/dc/terms/subject
|
http://dbpedia.org/resource/Category:Magnetic_resonance_imaging +
|
http://purl.org/linguistics/gold/hypernym
|
http://dbpedia.org/resource/Technique +
|
http://www.w3.org/ns/prov#wasDerivedFrom
|
http://en.wikipedia.org/wiki/Steady-state_free_precession_imaging?oldid=1123007110&ns=0 +
|
http://xmlns.com/foaf/0.1/depiction
|
http://commons.wikimedia.org/wiki/Special:FilePath/Four_chamber_cardiovascular_magnetic_resonance_imaging.gif +
|
http://xmlns.com/foaf/0.1/isPrimaryTopicOf
|
http://en.wikipedia.org/wiki/Steady-state_free_precession_imaging +
|
owl:sameAs |
http://rdf.freebase.com/ns/m.0fb36f +
, http://dbpedia.org/resource/Steady-state_free_precession_imaging +
, https://global.dbpedia.org/id/4vQSN +
, http://www.wikidata.org/entity/Q7605197 +
, http://ar.dbpedia.org/resource/%D8%AA%D8%B5%D9%88%D9%8A%D8%B1_%D8%A7%D9%84%D9%85%D8%AF%D9%88%D8%A7%D8%B1%D8%A9_%D8%A7%D9%84%D8%AD%D8%B1%D8%A9_%D9%84%D8%AD%D8%A7%D9%84%D8%A9_%D8%A7%D9%84%D8%A7%D8%B6%D8%B7%D8%B1%D8%A7%D8%AF +
, http://zh.dbpedia.org/resource/%E7%A9%A9%E5%AE%9A%E6%85%8B%E8%87%AA%E7%94%B1%E6%97%8B%E9%80%B2%E9%80%A0%E5%BD%B1 +
|
rdf:type |
http://dbpedia.org/ontology/TopicalConcept +
|
rdfs:comment |
Steady-state free precession (SSFP) imagin … Steady-state free precession (SSFP) imaging is a magnetic resonance imaging (MRI) sequence which uses steady states of magnetizations. In general, SSFP MRI sequences are based on a (low flip angle) gradient echo MRI sequence with a short repetition time which in its generic form has been described as the FLASH MRI technique. While spoiled gradient-echo sequences refer to a steady state of the longitudinal magnetization only, SSFP gradient-echo sequences include transverse coherences (magnetizations) from overlapping multi-order spin echoes and stimulated echoes. This is usually accomplished by refocusing the phase-encoding gradient in each repetition interval in order to keep the phase integral (or gradient moment) constant. Fully balanced SSFP MRI sequences achieve a phase of zero by refo sequences achieve a phase of zero by refo
, 穩定態自由旋進造影(steady-state free precession, SSFP, imaging)利用到核磁共振中的一種特殊穩定態達成的造影方式,一般分類上屬於梯度迴訊家族。旋進亦稱為進動,因而在翻譯上,此技術可能有些不一樣的名字,中國大陆地区譯作穩態自由進動成像、定常态自由进动成像。
, تصوير المدوارة الحرة لحالة الاضطراد هو عبارة عن تتابع للتصوير بالرنين المغناطيسي يستخدم حالة الاضطراد للمغنطة، ويعتمد على تتابع تدرج الصدى مع تقصير وقت التكرار.
|
rdfs:label |
Steady-state free precession imaging
, 穩定態自由旋進造影
, تصوير المدوارة الحرة لحالة الاضطراد
|