Browse Wiki & Semantic Web

Jump to: navigation, search
Http://dbpedia.org/resource/Power factor
  This page has no properties.
hide properties that link here 
  No properties link to this page.
 
http://dbpedia.org/resource/Power_factor
http://dbpedia.org/ontology/abstract La faktoro de povumo estas karakteriza graLa faktoro de povumo estas karakteriza grando de elektra ricevilo. Ĝi egalas al la kvociento de la aktiva povumo transdonita al la ricevilo per la ŝajna povumo. La valoro de estas ĉiam inter 0 kaj 1. Se la kurento kaj la tensio estas sinusaj funkcioj de la tempo, la faktoro de povumo egalas al la kosinuso de la inter la kurento kaj la tensio.nuso de la inter la kurento kaj la tensio. , In electrical engineering, the power factoIn electrical engineering, the power factor of an AC power system is defined as the ratio of the real power absorbed by the load to the apparent power flowing in the circuit. Real power is the average of the instantaneous product of voltage and current and represents the capacity of the electricity for performing work. Apparent power is the product of RMS current and voltage. Due to energy stored in the load and returned to the source, or due to a non-linear load that distorts the wave shape of the current drawn from the source, the apparent power may be greater than the real power, so more current flows in the circuit than would be required to transfer real power alone. A power factor magnitude of less than one indicates the voltage and current are not in phase, reducing the average product of the two. A negative power factor occurs when the device (which is normally the load) generates real power, which then flows back towards the source. In an electric power system, a load with a low power factor draws more current than a load with a high power factor for the same amount of useful power transferred. The higher currents increase the energy lost in the distribution system and require larger wires and other equipment. Because of the costs of larger equipment and wasted energy, electrical utilities will usually charge a higher cost to industrial or commercial customers where there is a low power factor. Power-factor correction increases the power factor of a load, improving efficiency for the distribution system to which it is attached. Linear loads with a low power factor (such as induction motors) can be corrected with a passive network of capacitors or inductors. Non-linear loads, such as rectifiers, distort the current drawn from the system. In such cases, active or passive power factor correction may be used to counteract the distortion and raise the power factor. The devices for correction of the power factor may be at a central substation, spread out over a distribution system, or built into power-consuming equipment., or built into power-consuming equipment. , 功率因数(英語:power factor,縮寫:PF)又称功率因子,是交流電力系統中功率因数(英語:power factor,縮寫:PF)又称功率因子,是交流電力系統中特有的物理量,是一負載所消耗的与其视在功率的比值,是0到1之間的無因次量。 有功功率代表一電路在特定時間作功的能力,视在功率是電壓和電流有效值的乘積。純電阻負載的视在功率等於有功功率,其功率因數為1。若負載是由電感、電容及電阻組成的線性負載,能量可能會在負載端及電源端往復流動,使得有功功率下降。若負載中有電感、電容及電阻以外的元件(非線性負載),會使得輸入電流的波形扭曲,也會使视在功率大於有功功率,這二種情形對應的功率因数會小於1。功率因数在一定程度上反映了发电机容量得以利用的比例,是合理用电的重要指标。 電力系統中,若一負載的功率因數較低,負載要產生相同功率輸出時所需要的電流就會提高。當電流提高時,電路系統的能量損失就會增加,而且電線及相關電力設備的容量也隨之增加。電力公司為了反映較大容量設備及浪費能量的成本,一般會對功率因數較低的工商業用戶以較高的電費費率來計算電費。 提高負載功率因數,使其接近1的技術稱為功率因數修正。低功率因數的線性負載(如感應馬達)可以藉由電感或電容組成的被動元件網路來提昇功因。非線性負載(如二極體)會使得輸入電流的波形扭曲,此情形可以由主動或被動的功率因數修正來抵消電流扭曲的影響,並且改善功因。功率因數修正設備可以位在中央變電站、分佈在電力系統中,或是放在耗能設備的內部。 功率因數和電效率二者是不同概念,一設備的效率是輸出功率相對於輸入功率的比值,和功因不同。一設備功率因數提昇後,設備本身的效率不一定會隨之提昇。但功率因數提昇後,視在功率及輸入電流會減小,因此供電系統的效率會提昇。定會隨之提昇。但功率因數提昇後,視在功率及輸入電流會減小,因此供電系統的效率會提昇。 , 力率(りきりつ、Power factor)は、交流電力の効率に関して定義された値であり、皮相電力に対する有効電力の割合である。料金計算などの電力の管理では、パーセントで表される。 , De arbeidsfactor of vermogensfactor is de De arbeidsfactor of vermogensfactor is de verhouding tussen het werkelijke vermogen en het schijnbare vermogen in een wisselspanningsinstallatie. Het schijnbare vermogen is het product van de effectieve waarde van de elektrische spanning en van de elektrische stroomsterkte, en wordt uitgedrukt in de eenheid voltampère: Het werkelijke vermogen is de per tijdseenheid overgebrachte hoeveelheid energie, het deel van het vermogen dat daadwerkelijk wordt omgezet in warmte en arbeid. Het wordt uitgedrukt in watt (W): In een gelijkstroomcircuit is het werkelijke vermogen gelijk aan het product van de spanning en de stroomsterkte: In een wisselspanningcircuit met alleen een ohmse impedantie geldt een dergelijke relatie voor de effectieve waarden: Is er ook een niet-ohmse (reactieve) component van de impedantie, dan is er een faseverschil tussen spanning en stroom, of ook is er een afwijking als gevolg van het niet-sinusvormig karakter van spanning of stroom.nusvormig karakter van spanning of stroom. , O fator de potência (FP) é uma relação entO fator de potência (FP) é uma relação entre potência ativa e potência reativa por consequência energia ativa e reativa. Ele pode ser usado para indicar se a proporção entre potência reativa e ativa está adequada. O fator de potência de um sistema elétrico qualquer, que está operando em corrente alternada (CA), é definido pela razão da potência real ou potência ativa pela potência total ou potência aparente. Um FP alto indica uma boa eficiência quanto ao uso de energia, significa dizer que grande parte da energia drenada é transformada em trabalho, inversamente a isso um fator de potência baixo indica que você não está aproveitando plenamente a energia drenada (entende-se por "energia drenada" a energia que você compra da concessionaria).nergia que você compra da concessionaria). , Faktor daya listrik adalah nilai perbandinFaktor daya listrik adalah nilai perbandingan antara dan . Rentang nilainya berkisar antara nol hingga satu. Faktor daya listrik dinyatakan dengan nilai cos φ. Pengamatan faktor daya listrik didasarkan pada jumlah arus listrik keseluruhan dalam suatu rangkaian listrik dan perbandingannya dengan jumlah arus yang terpakai. Pengambaran faktor daya dilakukan melalui sudut kosinus antara arus listrik dan tegangan listrik yang bekerja pada suatu . Faktor daya berguna untuk mengetahui tingkat efisiensi energi pada suatu beban listrik melalui nilai daya yang tidak terpakai dan terbuang sia-sia selama beban bekerja.dan terbuang sia-sia selama beban bekerja. , In ingegneria elettrica, il fattore di potIn ingegneria elettrica, il fattore di potenza di un sistema elettrico a corrente alternata è il rapporto fra il modulo del vettore potenza attiva che alimenta un carico elettrico e il modulo del vettore potenza apparente che fluisce nel circuito. In un sistema con carichi lineari coincide con il coseno dell'angolo di sfasamento compreso tra i vettori tensione e corrente. È un numero adimensionale nell'intervallo chiuso tra -1 e 1. La potenza attiva è la capacità di un circuito di fornire un lavoro meccanico nell'unità di tempo t, ed è pari al prodotto scalare tra i vettori tensione (V) e corrente (I). La potenza apparente è il prodotto algebrico della tensione e della corrente circolanti in un circuito nell'istante t, preso in valore assoluto, in modulo, e rappresenta la potenza elettrica effettivamente circolante.In generale, la potenza apparente è maggiore della potenza attiva e la potenza attiva coincide con la potenza apparente solo quando il vettore corrente elettrica è concorde col vettore tensione elettrica, il che accade unicamente nel circuito ideale che contiene unicamente elementi dissipativi ideali detti resistori. Questo si verifica nei circuiti elettrici reali di piccola lunghezza in cui sono presenti solo resistenze elettriche, fatte le dovute approssimazioni, ovvero con piccoli scostamenti tra i valori di corrente attesi (teorici) e quelli misurati (reali) alle varie tensioni applicate. In tutti i casi reali differenti da questo, il vettore corrente che fluisce nel circuito non è in fase con il vettore tensione che l'ha generata per la presenza di fenomeni fisici riferibili alla capacità e all'induttanza. Va ricordato che la sollecitazione applicata al circuito, ovvero la tensione, è una grandezza alternata, rappresentabile come una generica grandezza sinusoidale, oscillante tra due valori, il massimo positivo e negativo, passante per zero, con frequenza costante, ovvero che si ripete con un periodo, un intervallo temporale, costante. Questo significa che le correnti generate sono variabili con la stessa frequenza della tensione (se nel circuito ci sono solo carichi lineari), ma a causa degli effetti induttivi e capacitivi i massimi, i minimi e gli zeri della corrente non sono contemporanei con i corrispettivi valori assunti dal vettore tensione in ciascun periodo: la corrente risulta "non in fase" ovvero sfasata in anticipo o in ritardo sulla tensione che l'ha generata. In altre parole, a causa del fatto che la potenza elettrica (e il flusso di energia) è immagazzinata in elementi del circuito reale quali induttori e condensatori elettrici, essa è restituita sfasata (in ritardo o in anticipo) nel tempo rispetto al vettore tensione del generatore: compaiono delle correnti non in fase con la tensione definite correnti reattive. In quasi tutti i circuiti reali, la corrente è in ritardo rispetto alla tensione e la potenza apparente risulta quasi sempre maggiore della potenza attiva. Importante considerare che nei circuiti reali la potenza attiva, quella che si trasforma tutta in potenza meccanica utile, è in realtà minore rispetto alla potenza apparente effettivamente circolante, dunque le dissipazioni del circuito (effetto termico per attrito del flusso di cariche attraverso il mezzo conduttore) proporzionali alla resistenza R (espressa dalla prima legge di Ohm) sono proporzionali alla potenza apparente: è utile ed opportuno ridurre queste perdite ovvero ridurre al minimo la componente della corrente non in fase con la tensione e questo si fa mediante l'aggiunta di un opportuno carico di rifasamento. In definitiva la grandezza elettrica fattore di potenza è utilizzata per dimensionare le due componenti attiva e reattiva in cui si può immaginare di scomporre il vettore potenza Apparente su un piano cartesiano ovvero in termini di seno e coseno, e si pone: con φ è indicato l'angolo di sfasamento, compreso tra il vettore tensione (V) e il vettore corrente (I). Per convenzione (coerente con i fenomeni fisici di capacità ed induttanza) si pone la tensione sull'asse x, la corrente reattiva capacitiva sull'asse positivo delle y e la corrente reattiva induttiva sull'asse negativo delle y.Ipotizzando per convenzione il verso antiorario di rotazione dei vettori sull'asse x, la corrente reattiva capacitiva è in anticipo rispetto alla tensione quindi la corrente reattiva induttiva in ritardo, con angolo di sfasamento φ = ± 90° = ± π/2 . Il valore negativo del fattore di potenza si ha quando il dispositivo definito carico, ovvero utenza, genera potenza. In questo caso la potenza fluisce dal circuito alla sorgente, al generatore, e il circuito stesso è considerato un generatore di energia. Se il circuito contiene uno o più carichi non-lineari (generalmente circuiti elettronici) si osserva anche una distorsione della forma d'onda della corrente ovvero una variazione della frequenza: alla frequenza generata dalla tensione, definita frequenza fondamentale (ad esempio 50 Hz in Europa) si aggiungono correnti con frequenze multiple della fondamentale dette di armonica superiore (ad esempio di terza armonica: 150 Hz, di quinta armonica: 250 Hz, di settima armonica: 350 Hz e così via)., di settima armonica: 350 Hz e così via). , 전기에는 직류와 교류가 존재하는데, 역률(영어: power factor)은 전기에는 직류와 교류가 존재하는데, 역률(영어: power factor)은 교류와 관계된다. 왜냐하면, 직류에서는 전압과 전류의 곱으로 전력이 되는데, 그 공식은 아래와 같이 나타낼 수 있다. P = 전력, V = 전압, I = 전류 직류에서는 위상이라는 개념이 없다. 하지만, 교류에서는 위상이 존재하며, 교류회로에서 역률은 (Active Power [단위 : W])과 (Apparent Power [단위 : VA])의 비를 말하는데, 이를 간단히 풀어서 해석하면, “전기설비에 걸리는 전압과 전류가 얼마나 효율적으로 일을 잘 하고 있는가?”로 나타내는 지표로도 활용된다. 역률은 유효전력을 피상전력(외관상의 전력)으로 나눈값이며, 교류 회로에서 전류와 전압의 위상차를 코사인 값(cosθ)으로 나타낸다. 직류에서는 전압과 전류만 곱하면 그것이 전력이었으나, 교류는 전압과 전류의 실효값을 곱한 피상전력이라는 것에 역률을 곱하여야 비로소 전력이 된다. 왜냐하면 직류처럼 일정한 흐름이 아닌, 정현파의 형태를 그리며 계속 지속적으로 변하기 때문이다. 즉, 직류처럼 일정한 값이 아닌, 계속 지속적으로 변하는 값이기 때문에 위상이 반드시 일치하지는 않는 것이다. 여기서 피상전력은 전압(V)과 전류(I)의 곱 (VI) 이므로, 피상전력의 공식은 아래와 같이 나타낼 수 있다. 여기서 AP는 유효전력 (Active Power) / RP는 (Reactive Power)을 말한다. 유효전력은 다음과 같이 나타낼 수 있다. (단, 위상각) 무효전력은 다음과 같이 나타낼 수 있다. (단, 위상각) 역률을 구하려면 유효전력을 피상전력으로 나누어야 하며, 그 수식은 아래와 같이 나타낼 수 있다. 역률은 위와 같이 나타낼 수 있으며, 보통 역률은 최대 1로 표기된다. 표시방식은 보통 "EX1) 0.90 ~ 0.95" / "EX2) 0.76 => 76%" 이렇게 표시된다. 역률이 1 즉, 100% 라는 얘기는 무효전력 아예 존재하지 않다는 것임을 의미하며, 이때 유효전력은 피상전력과 같아지게 된다. 우리가 한전에서 전기요금 명세서를 받아보면, 거기에는 주거용(가정용)역률 90%[0.9]로 감안하여 전기요금에 반영이 되어있는데, 이는 가정집에서는 세탁기, 냉장고 등 전동기(코일 성분)로 동작을 시키기 때문에 주거용(가정용)역률은 100%가 될 수 없다. 시퀀스 회로도로 보면 알 수 있겠지만, 전동기로 기동이 되는 것은 거의 코일이 포함되어 있기 때문에 역률이 100%로 맞춰지지 못한다. 전압과 전류의 위상차이는 전력을 효율적으로 사용하지 못하는 무효전력을 발생시키고 이는 역률에 관계된다. 실제 수용가 측면에서는 초기 투자비의 과다와 실제 부하사용량에 따라 역률제어 실행 시 필요한 역률조정소자의 용량이 달라지기 때문에 건축전기설비설계 시 역률개선을 위한 역률제어반을 설치하지 않고 부하운용을 먼저 한 후, 역률제어반을 설치하게 되는데 이는 나중에 설치하게 되면 제한된 전기실의 공간으로 인하여 설치하기가 어려워지는 상황이 자주 발생됨. 저항(R)만 존재할 때, 회로의 역률은 전압과 전류의 위상이 없기 때문에 역률은 1로 나타낼 수 있다. 코일(L)만 존재할 때, 전압과 전류의 관계식은 으로 나타낼 수 있으며, 이는 전압을 기준으로 할 때 전류는 90도가 늦어져 위상이 90도 차이가 나게 되어, 역률은 0이 된다. 이러한 과정에 의하여 역률은 0이 되어, 전류는 전압보다 위상이 90도 늦지게 됨. 정전용량(C)만 존재할 때, 전압과 전류의 관계식은 으로 나타낼 수 있으며, 이는 전압을 기준으로 할 때 전류는 90도가 빨라져 위상이 90도 차이가 나게 되어, 코일만의 회로와 마찬가지로 역률은 0이 된다.이 90도 차이가 나게 되어, 코일만의 회로와 마찬가지로 역률은 0이 된다. , Коефіціє́нт поту́жності — безрозмірна фізиКоефіціє́нт поту́жності — безрозмірна фізична величина, що означує споживача змінного електричного струму з точки зору наявності в навантаженні реактивної складової. Коефіцієнт потужності показує, наскільки зсувається по фазі змінний струм, що протікає крізь навантаження, щодо прикладеної до нього напруги. Чисельно коефіцієнт потужності дорівнює косинусу цього фазового зсуву.ті дорівнює косинусу цього фазового зсуву. , Účiník je kosinus vzájemného fázového posuÚčiník je kosinus vzájemného fázového posuvu mezi proudem a napětím elektrického obvodu s harmonickými průběhy střídavých proudů a napětí či periodickými průběhy o jednotlivých harmonických složkách proudů a napětí. Účiník je poměrem činného a zdánlivého elektrického výkonu v obvodu střídavého proudu a napětí, vyjadřuje, jak velkou část zdánlivého výkonu přeměňuje obvod na činný výkon, tj. na součet užitečného výkonu a ztrát. Hodnota účiníku se pohybuje od nuly do jedné, při účiníku rovném jedné je zdánlivý výkon roven činnému výkonu (fázový posuv je nulový). Při nulovém účiníku je zdánlivý výkon roven jalovému výkonu, zátěž je buď čistě induktivní (fázový posuv je , tj. proud se zpožďuje za napětím) nebo čistě kapacitní (fázový posuv je , tj. napětí se zpožďuje za proudem). Hodnota účiníku menší než jedna způsobuje nežádoucí zvýšené ztráty energie přenášené vedením od zdroje ke spotřebiči. Značka: Jednotka SI: -roje ke spotřebiči. Značka: Jednotka SI: - , Se define factor de potencia, f.d.p., de un circuito de corriente alterna, potencia activa, P, y la potencia aparente, S.​Da una medida de la capacidad de una carga de absorber potencia activa. Por esta razón, f.d.p = 1 en cargas puramente resistivas. , Коэффицие́нт мо́щности — безразмерная физиКоэффицие́нт мо́щности — безразмерная физическая величина, характеризующая потребителя переменного электрического тока с точки зрения наличия в нагрузке реактивной составляющей и мощности искажения (собирательное название — неактивная мощность). Следует отличать понятие «коэффициент мощности» от понятия «косинус фи», который равен косинусу сдвига фазы переменного тока, протекающего через нагрузку, относительно приложенного к ней напряжения. Второе понятие используют в случае синусоидальных тока и напряжения, и только в этом случае оба понятия эквивалентны.ко в этом случае оба понятия эквивалентны. , Als Leistungsfaktor (auch WirkleistungsfakAls Leistungsfaktor (auch Wirkleistungsfaktor) wird in der elektrischen Wechselstromtechnik das Verhältnis vom Betrag der Wirkleistung zur Scheinleistung bezeichnet. Das Verhältnis wird in folgender Formel ausgedrückt: Der Leistungsfaktor kann zwischen 0 und 1 liegen:stungsfaktor kann zwischen 0 und 1 liegen: , En enginyeria elèctrica, el factor de potèEn enginyeria elèctrica, el factor de potència d'un sistema de potència elèctric de corrent altern es defineix com la ràtio entre la potència real i la potència aparent. És un paràmetre sense dimensions i el seu interval va de -1 A +1. El seu símbol és FP o també cos φ. Les càrregues resistives pures tenen un FP=1, en canvi les càrregues inductives pures (inductives o capacitives) tenen un FP=0. (inductives o capacitives) tenen un FP=0. , Le facteur de puissance est une caractérisLe facteur de puissance est une caractéristique d'un récepteur électrique qui rend compte de son efficacité pour consommer de la puissance lorsqu'il est traversé par un courant. Pour un dipôle électrique alimenté en régime de courant variable au cours du temps (sinusoïdal ou non), il est égal à la puissance active P consommée par ce dipôle, divisée par le produit des valeurs efficaces du courant I et de la tension U (puissance apparente S). Il est toujours compris entre 0 et 1. En particulier, si le courant et la tension sont des fonctions sinusoïdales du temps, le facteur de puissance est égal au cosinus du déphasage entre le courant et la tension :déphasage entre le courant et la tension : , معامل القدرة (Power Factor) هو النسبة بين معامل القدرة (Power Factor) هو النسبة بين إلى ، وهو مساوِ لجيب تمام زاوية الطور (cos_phi) - والتي هي فرق زاويتي الجهد والتيار. لذا فهو قيمة عددية ليس لها وحدة قياس تتراوح من الصفر إلى الواحد، في محطات القدرة يحبذ ويتم السعي إلى أن يكون معامل القدرة أكبر ما يمكن حيث أنه بزيادة درجة معامل القدرة يزداد مقدارالقدرة الفعالة وتنخفض القيمة أو وتتراوح قيم معاملات القدرة في محطات القدرة التي تعتمد نظام التيار المتردد الأحمال الكهربائية تقع في إحدى التصنيفات التالية: * مقاوِم Resistive * حثي Inductive * سعوي Capacitive والأحمال الكهربائية الأكثر شيوعاً هي الأحمال الحثية ومثال عليها: المحولات الكهربائية ومحركات التيار المستمر الحثية. وجميع هذه الأحمال (الحثية) تحتاج إلى نوعين من القدرة الكهربائية لكي تعمل: القدرة الفعّآلة أو القدرة الحقيقية Active Power or Real Power - KWالقدرة غير الفعّآلة Reactive Power - KVARالقدرة الفعّآلة هي القدرة المفيدة في الشبكة الكهربائية في حين أن القدرة غير الفعالة لا دور لها سوى توليد المجال المغناطيسي اللازم لعمل الأحمال الحثية. وفي جميع الأحوال، على شركات تزويد الطاقة الكهربائية تزويد التيار إلى أحمال المستهلكين بغض النظر أكانت مقاومية، سعوية أو حثية. وهذا التيار بلا شك، سيولّد طاقة مهدورة في خطوط النقل الكهربائي بحسب العلاقةمعامل القدرة الكهربائية يعني تزويد طاقة ظاهرة أكثر من الطاقة الفعالة وتدني معامل القدرة الكهربائية يؤدي إلى زيادة في توليد التيار للتعويض مما يؤدي إلى خسائر الطاقةد التيار للتعويض مما يؤدي إلى خسائر الطاقة , Współczynnik mocy, – stosunek mocy czynnejWspółczynnik mocy, – stosunek mocy czynnej do mocy pozornej, czyli stosunek mocy użytecznej do iloczynu napięcia i prądu. Powszechnie dziś stosowane w elektrotechnice pojęcie współczynnika mocy wprowadził pod koniec XIX wieku uczony polskiego pochodzenia Michał Doliwo-Dobrowolski pracujący wówczas w niemieckim koncernie AEG. W obwodach zasilanych napięciem sinusoidalnie zmiennym, a powodujących powstawanie prądu o przebiegach okresowych niesinusoidalnych, rozpatruje się bardzo często dwie składowe współczynnika mocy: * – składową związaną z przesunięciem fazowym między pierwszą harmoniczną prądu i napięciem; * – składowa związana z odkształceniem przebiegów prądu w stosunku do przebiegu napięcia. Całkowity współczynnik mocy wynosi wtedy: Moc czynną, bierną i pozorną można przedstawić graficznie w postaci trójkąta prostokątnego, zwanego trójkątem mocy. Z trójkąta tego wynika, że współczynnik mocy jest ilorazem mocy czynnej i pozornej: gdzie: – moc czynna, – moc pozorna (zespolona). Przy sinusoidalnym napięciu zasilania: Odbiorniki prądu przemiennego pobierają ze źródła moc pozorną a oddają na zewnątrz moc czynną w postaci energii cieplnej lub mechanicznej (wykonanej pracy).eplnej lub mechanicznej (wykonanej pracy).
http://dbpedia.org/ontology/thumbnail http://commons.wikimedia.org/wiki/Special:FilePath/Power_Factor_General_Case.svg?width=300 +
http://dbpedia.org/ontology/wikiPageExternalLink http://www.ece.utexas.edu/~grady/POWERFAC.pdf +
http://dbpedia.org/ontology/wikiPageID 41568
http://dbpedia.org/ontology/wikiPageLength 46539
http://dbpedia.org/ontology/wikiPageRevisionID 1124211251
http://dbpedia.org/ontology/wikiPageWikiLink http://dbpedia.org/resource/Joule_heating + , http://dbpedia.org/resource/Solenoid + , http://dbpedia.org/resource/Polyphase_system + , http://dbpedia.org/resource/Utility_frequency + , http://dbpedia.org/resource/Ground_and_neutral + , http://dbpedia.org/resource/Mains_electricity + , http://dbpedia.org/resource/Buck_converter + , http://dbpedia.org/resource/Ammeter + , http://dbpedia.org/resource/Dimensionless_number + , http://dbpedia.org/resource/Welding + , http://dbpedia.org/resource/Contactor + , http://dbpedia.org/resource/Physical_quantity + , http://dbpedia.org/resource/Phase_%28waves%29 + , http://dbpedia.org/resource/File:Condensor_bank_150kV_-_75MVAR.jpg + , http://dbpedia.org/resource/Linear + , http://dbpedia.org/resource/Valley-fill_circuit + , http://dbpedia.org/resource/Vienna_rectifier + , http://dbpedia.org/resource/Total_harmonic_distortion + , http://dbpedia.org/resource/IEC_EN_61000-3-2 + , http://dbpedia.org/resource/Buck-boost_converter + , http://dbpedia.org/resource/Eddy_currents + , http://dbpedia.org/resource/Magnetic_field + , http://dbpedia.org/resource/Volt-amperes + , http://dbpedia.org/resource/Ratio + , http://dbpedia.org/resource/Watt + , http://dbpedia.org/resource/Electric_field + , http://dbpedia.org/resource/Electrical_ballast + , http://dbpedia.org/resource/Electric_motor + , http://dbpedia.org/resource/Electrical_engineering + , http://dbpedia.org/resource/STATCOM + , http://dbpedia.org/resource/Electrical_load + , http://dbpedia.org/resource/Reactance_%28electronics%29 + , http://dbpedia.org/resource/Apparent_power + , http://dbpedia.org/resource/Electric_arc_furnace + , http://dbpedia.org/resource/Category:AC_power + , http://dbpedia.org/resource/AC_power + , http://dbpedia.org/resource/Thyristor + , http://dbpedia.org/resource/Harmonic + , http://dbpedia.org/resource/Bridge_rectifier + , http://dbpedia.org/resource/Category:Electrical_engineering + , http://dbpedia.org/resource/Power_electronics + , http://dbpedia.org/resource/Electric_power_transmission + , http://dbpedia.org/resource/Boost_converter + , http://dbpedia.org/resource/Rectifiers + , http://dbpedia.org/resource/SI + , http://dbpedia.org/resource/Harmonics_%28electrical_power%29 + , http://dbpedia.org/resource/Electrical_substation + , http://dbpedia.org/resource/Voltage + , http://dbpedia.org/resource/Overvoltage + , http://dbpedia.org/resource/File:Active_pfc_PSU_packaging.png + , http://dbpedia.org/resource/Inductor + , http://dbpedia.org/resource/European_Union + , http://dbpedia.org/resource/Arc_furnace + , http://dbpedia.org/resource/File:Condensatorenbatterij.jpg + , http://dbpedia.org/resource/File:Lagging-Leading.jpg + , http://dbpedia.org/resource/File:Power_factor_0.7.svg + , http://dbpedia.org/resource/File:Power_factor_0.svg + , http://dbpedia.org/resource/File:Power_triangle_diagram.jpg + , http://dbpedia.org/resource/File:Power_factor_75_2.png + , http://dbpedia.org/resource/File:Blindleistungskompensation.svg + , http://dbpedia.org/resource/File:Power_Factor_General_Case.svg + , http://dbpedia.org/resource/Category:Engineering_ratios + , http://dbpedia.org/resource/80_Plus + , http://dbpedia.org/resource/Wattmeter + , http://dbpedia.org/resource/Delta-wye_transformer + , http://dbpedia.org/resource/Rectifier + , http://dbpedia.org/resource/Switched-mode_power_supply + , http://dbpedia.org/resource/Non-linear + , http://dbpedia.org/resource/Category:Electrical_parameters + , http://dbpedia.org/resource/United_States_Environmental_Protection_Agency + , http://dbpedia.org/resource/Fluorescent_lamp + , http://dbpedia.org/resource/Sine_wave + , http://dbpedia.org/resource/Real_power + , http://dbpedia.org/resource/Peak-to-average_ratio + , http://dbpedia.org/resource/Static_VAR_compensator + , http://dbpedia.org/resource/Energy_Star + , http://dbpedia.org/resource/Synchronous_condenser + , http://dbpedia.org/resource/Electric_power_grid + , http://dbpedia.org/resource/Synchronous_motor + , http://dbpedia.org/resource/Steel_mill + , http://dbpedia.org/resource/Induction_motor + , http://dbpedia.org/resource/Electrical_network + , http://dbpedia.org/resource/Root_mean_square + , http://dbpedia.org/resource/Voltmeter + , http://dbpedia.org/resource/Volt-ampere_reactive + , http://dbpedia.org/resource/Capacitor + , http://dbpedia.org/resource/Power_supply_unit_%28computer%29 + , http://dbpedia.org/resource/Three-phase_electric_power + , http://dbpedia.org/resource/Reactive_power + , http://dbpedia.org/resource/Moving_coil_meter + , http://dbpedia.org/resource/Linear_time-invariant_system + , http://dbpedia.org/resource/High-voltage_direct_current + , http://dbpedia.org/resource/Trigonometric_functions + , http://dbpedia.org/resource/Product_%28mathematics%29 + , http://dbpedia.org/resource/Electronic_filter +
http://dbpedia.org/property/wikiPageUsesTemplate http://dbpedia.org/resource/Template:Electricity_delivery + , http://dbpedia.org/resource/Template:For + , http://dbpedia.org/resource/Template:Mvar + , http://dbpedia.org/resource/Template:Reflist + , http://dbpedia.org/resource/Template:Main + , http://dbpedia.org/resource/Template:Short_description + , http://dbpedia.org/resource/Template:Citation + , http://dbpedia.org/resource/Template:= + , http://dbpedia.org/resource/Template:Authority_control +
http://purl.org/dc/terms/subject http://dbpedia.org/resource/Category:Electrical_engineering + , http://dbpedia.org/resource/Category:AC_power + , http://dbpedia.org/resource/Category:Engineering_ratios + , http://dbpedia.org/resource/Category:Electrical_parameters +
http://purl.org/linguistics/gold/hypernym http://dbpedia.org/resource/Number +
http://www.w3.org/ns/prov#wasDerivedFrom http://en.wikipedia.org/wiki/Power_factor?oldid=1124211251&ns=0 +
http://xmlns.com/foaf/0.1/depiction http://commons.wikimedia.org/wiki/Special:FilePath/Power_Factor_General_Case.svg + , http://commons.wikimedia.org/wiki/Special:FilePath/Power_factor_0.7.svg + , http://commons.wikimedia.org/wiki/Special:FilePath/Power_factor_0.svg + , http://commons.wikimedia.org/wiki/Special:FilePath/Power_factor_75_2.png + , http://commons.wikimedia.org/wiki/Special:FilePath/Lagging-Leading.jpg + , http://commons.wikimedia.org/wiki/Special:FilePath/Power_triangle_diagram.jpg + , http://commons.wikimedia.org/wiki/Special:FilePath/Condensatorenbatterij.jpg + , http://commons.wikimedia.org/wiki/Special:FilePath/Condensor_bank_150kV_-_75MVAR.jpg + , http://commons.wikimedia.org/wiki/Special:FilePath/Active_pfc_PSU_packaging.png + , http://commons.wikimedia.org/wiki/Special:FilePath/Blindleistungskompensation.svg +
http://xmlns.com/foaf/0.1/isPrimaryTopicOf http://en.wikipedia.org/wiki/Power_factor +
owl:sameAs http://it.dbpedia.org/resource/Fattore_di_potenza + , http://es.dbpedia.org/resource/Factor_de_potencia + , http://su.dbpedia.org/resource/Faktor_daya + , http://id.dbpedia.org/resource/Faktor_daya_listrik + , http://et.dbpedia.org/resource/V%C3%B5imsustegur + , http://uk.dbpedia.org/resource/%D0%9A%D0%BE%D0%B5%D1%84%D1%96%D1%86%D1%96%D1%94%D0%BD%D1%82_%D0%BF%D0%BE%D1%82%D1%83%D0%B6%D0%BD%D0%BE%D1%81%D1%82%D1%96 + , http://fi.dbpedia.org/resource/Tehokerroin + , http://yago-knowledge.org/resource/Power_factor + , http://ka.dbpedia.org/resource/%E1%83%A1%E1%83%98%E1%83%9B%E1%83%AB%E1%83%9A%E1%83%90%E1%83%95%E1%83%A0%E1%83%98%E1%83%A1_%E1%83%99%E1%83%9D%E1%83%94%E1%83%A4%E1%83%98%E1%83%AA%E1%83%98%E1%83%94%E1%83%9C%E1%83%A2%E1%83%98 + , http://simple.dbpedia.org/resource/Power_factor + , http://hi.dbpedia.org/resource/%E0%A4%B6%E0%A4%95%E0%A5%8D%E0%A4%A4%E0%A4%BF_%E0%A4%97%E0%A5%81%E0%A4%A3%E0%A4%BE%E0%A4%82%E0%A4%95 + , http://vi.dbpedia.org/resource/H%E1%BB%87_s%E1%BB%91_c%C3%B4ng_su%E1%BA%A5t + , http://dbpedia.org/resource/Power_factor + , https://global.dbpedia.org/id/4uXuB + , http://lmo.dbpedia.org/resource/Fator_de_potenza + , http://bg.dbpedia.org/resource/%D0%A4%D0%B0%D0%BA%D1%82%D0%BE%D1%80_%D0%BD%D0%B0_%D0%BC%D0%BE%D1%89%D0%BD%D0%BE%D1%81%D1%82%D1%82%D0%B0 + , http://pl.dbpedia.org/resource/Wsp%C3%B3%C5%82czynnik_mocy + , http://pa.dbpedia.org/resource/%E0%A8%AA%E0%A8%BE%E0%A8%B5%E0%A8%B0_%E0%A8%AB%E0%A8%BC%E0%A9%88%E0%A8%95%E0%A8%9F%E0%A8%B0 + , http://cs.dbpedia.org/resource/%C3%9A%C4%8Din%C3%ADk + , http://ro.dbpedia.org/resource/Factor_de_putere + , http://fr.dbpedia.org/resource/Facteur_de_puissance + , http://eo.dbpedia.org/resource/Faktoro_de_povumo + , http://zh.dbpedia.org/resource/%E5%8A%9F%E7%8E%87%E5%9B%A0%E6%95%B0 + , http://sk.dbpedia.org/resource/%C3%9A%C4%8Dinn%C3%ADk + , http://my.dbpedia.org/resource/%E1%80%95%E1%80%AB%E1%80%9D%E1%80%AB%E1%80%8A%E1%80%BD%E1%80%BE%E1%80%94%E1%80%BA%E1%80%B8%E1%80%80%E1%80%AD%E1%80%94%E1%80%BA%E1%80%B8 + , http://gl.dbpedia.org/resource/Factor_de_potencia + , http://ko.dbpedia.org/resource/%EC%97%AD%EB%A5%A0 + , http://fa.dbpedia.org/resource/%D8%B6%D8%B1%DB%8C%D8%A8_%D8%AA%D9%88%D8%A7%D9%86 + , http://ru.dbpedia.org/resource/%D0%9A%D0%BE%D1%8D%D1%84%D1%84%D0%B8%D1%86%D0%B8%D0%B5%D0%BD%D1%82_%D0%BC%D0%BE%D1%89%D0%BD%D0%BE%D1%81%D1%82%D0%B8 + , http://rdf.freebase.com/ns/m.0bdwm + , http://de.dbpedia.org/resource/Leistungsfaktor + , http://www.wikidata.org/entity/Q750454 + , http://ar.dbpedia.org/resource/%D9%85%D8%B9%D8%A7%D9%85%D9%84_%D8%A7%D9%84%D9%82%D8%AF%D8%B1%D8%A9 + , http://ca.dbpedia.org/resource/Factor_de_pot%C3%A8ncia + , http://he.dbpedia.org/resource/%D7%9E%D7%A7%D7%93%D7%9D_%D7%94%D7%A1%D7%A4%D7%A7 + , http://pt.dbpedia.org/resource/Fator_de_pot%C3%AAncia + , http://lv.dbpedia.org/resource/Jaudas_koeficients + , http://d-nb.info/gnd/4167276-8 + , http://pnb.dbpedia.org/resource/%D9%BE%D8%A7%D9%88%D8%B1_%D9%81%DB%8C%DA%A9%D9%B9%D8%B1 + , http://ja.dbpedia.org/resource/%E5%8A%9B%E7%8E%87 + , http://ms.dbpedia.org/resource/Faktor_kuasa + , http://sr.dbpedia.org/resource/%D0%A4%D0%B0%D0%BA%D1%82%D0%BE%D1%80_%D1%81%D0%BD%D0%B0%D0%B3%D0%B5 + , http://bn.dbpedia.org/resource/%E0%A6%AA%E0%A6%BE%E0%A6%93%E0%A6%AF%E0%A6%BC%E0%A6%BE%E0%A6%B0_%E0%A6%AB%E0%A7%8D%E0%A6%AF%E0%A6%BE%E0%A6%95%E0%A7%8D%E0%A6%9F%E0%A6%B0 + , http://tr.dbpedia.org/resource/G%C3%BC%C3%A7_fakt%C3%B6r%C3%BC + , http://nl.dbpedia.org/resource/Arbeidsfactor +
rdf:type http://dbpedia.org/class/yago/PsychologicalFeature100023100 + , http://dbpedia.org/class/yago/Concept105835747 + , http://dbpedia.org/class/yago/Idea105833840 + , http://dbpedia.org/class/yago/Content105809192 + , http://dbpedia.org/class/yago/Constant105858936 + , http://dbpedia.org/class/yago/Quantity105855125 + , http://dbpedia.org/class/yago/Parameter105859071 + , http://dbpedia.org/class/yago/WikicatElectricalParameters + , http://dbpedia.org/class/yago/Cognition100023271 + , http://dbpedia.org/class/yago/Abstraction100002137 +
rdfs:comment معامل القدرة (Power Factor) هو النسبة بين معامل القدرة (Power Factor) هو النسبة بين إلى ، وهو مساوِ لجيب تمام زاوية الطور (cos_phi) - والتي هي فرق زاويتي الجهد والتيار. لذا فهو قيمة عددية ليس لها وحدة قياس تتراوح من الصفر إلى الواحد، في محطات القدرة يحبذ ويتم السعي إلى أن يكون معامل القدرة أكبر ما يمكن حيث أنه بزيادة درجة معامل القدرة يزداد مقدارالقدرة الفعالة وتنخفض القيمة أو وتتراوح قيم معاملات القدرة في محطات القدرة التي تعتمد نظام التيار المتردد الأحمال الكهربائية تقع في إحدى التصنيفات التالية: * مقاوِم Resistive * حثي Inductive * سعوي Capacitiveistive * حثي Inductive * سعوي Capacitive , La faktoro de povumo estas karakteriza graLa faktoro de povumo estas karakteriza grando de elektra ricevilo. Ĝi egalas al la kvociento de la aktiva povumo transdonita al la ricevilo per la ŝajna povumo. La valoro de estas ĉiam inter 0 kaj 1. Se la kurento kaj la tensio estas sinusaj funkcioj de la tempo, la faktoro de povumo egalas al la kosinuso de la inter la kurento kaj la tensio.nuso de la inter la kurento kaj la tensio. , De arbeidsfactor of vermogensfactor is de De arbeidsfactor of vermogensfactor is de verhouding tussen het werkelijke vermogen en het schijnbare vermogen in een wisselspanningsinstallatie. Het schijnbare vermogen is het product van de effectieve waarde van de elektrische spanning en van de elektrische stroomsterkte, en wordt uitgedrukt in de eenheid voltampère: Het werkelijke vermogen is de per tijdseenheid overgebrachte hoeveelheid energie, het deel van het vermogen dat daadwerkelijk wordt omgezet in warmte en arbeid. Het wordt uitgedrukt in watt (W): arbeid. Het wordt uitgedrukt in watt (W): , Faktor daya listrik adalah nilai perbandinFaktor daya listrik adalah nilai perbandingan antara dan . Rentang nilainya berkisar antara nol hingga satu. Faktor daya listrik dinyatakan dengan nilai cos φ. Pengamatan faktor daya listrik didasarkan pada jumlah arus listrik keseluruhan dalam suatu rangkaian listrik dan perbandingannya dengan jumlah arus yang terpakai. Pengambaran faktor daya dilakukan melalui sudut kosinus antara arus listrik dan tegangan listrik yang bekerja pada suatu . Faktor daya berguna untuk mengetahui tingkat efisiensi energi pada suatu beban listrik melalui nilai daya yang tidak terpakai dan terbuang sia-sia selama beban bekerja.dan terbuang sia-sia selama beban bekerja. , O fator de potência (FP) é uma relação entO fator de potência (FP) é uma relação entre potência ativa e potência reativa por consequência energia ativa e reativa. Ele pode ser usado para indicar se a proporção entre potência reativa e ativa está adequada. O fator de potência de um sistema elétrico qualquer, que está operando em corrente alternada (CA), é definido pela razão da potência real ou potência ativa pela potência total ou potência aparente. Um FP alto indica uma boa eficiência quanto ao uso de energia, significa dizer que grande parte da energia drenada é transformada em trabalho, inversamente a isso um fator de potência baixo indica que você não está aproveitando plenamente a energia drenada (entende-se por "energia drenada" a energia que você compra da concessionaria).nergia que você compra da concessionaria). , Współczynnik mocy, – stosunek mocy czynnejWspółczynnik mocy, – stosunek mocy czynnej do mocy pozornej, czyli stosunek mocy użytecznej do iloczynu napięcia i prądu. Powszechnie dziś stosowane w elektrotechnice pojęcie współczynnika mocy wprowadził pod koniec XIX wieku uczony polskiego pochodzenia Michał Doliwo-Dobrowolski pracujący wówczas w niemieckim koncernie AEG. W obwodach zasilanych napięciem sinusoidalnie zmiennym, a powodujących powstawanie prądu o przebiegach okresowych niesinusoidalnych, rozpatruje się bardzo często dwie składowe współczynnika mocy: Całkowity współczynnik mocy wynosi wtedy: gdzie:ity współczynnik mocy wynosi wtedy: gdzie: , 力率(りきりつ、Power factor)は、交流電力の効率に関して定義された値であり、皮相電力に対する有効電力の割合である。料金計算などの電力の管理では、パーセントで表される。 , En enginyeria elèctrica, el factor de potèEn enginyeria elèctrica, el factor de potència d'un sistema de potència elèctric de corrent altern es defineix com la ràtio entre la potència real i la potència aparent. És un paràmetre sense dimensions i el seu interval va de -1 A +1. El seu símbol és FP o també cos φ. Les càrregues resistives pures tenen un FP=1, en canvi les càrregues inductives pures (inductives o capacitives) tenen un FP=0. (inductives o capacitives) tenen un FP=0. , Le facteur de puissance est une caractérisLe facteur de puissance est une caractéristique d'un récepteur électrique qui rend compte de son efficacité pour consommer de la puissance lorsqu'il est traversé par un courant. Pour un dipôle électrique alimenté en régime de courant variable au cours du temps (sinusoïdal ou non), il est égal à la puissance active P consommée par ce dipôle, divisée par le produit des valeurs efficaces du courant I et de la tension U (puissance apparente S). Il est toujours compris entre 0 et 1. S). Il est toujours compris entre 0 et 1. , Se define factor de potencia, f.d.p., de un circuito de corriente alterna, potencia activa, P, y la potencia aparente, S.​Da una medida de la capacidad de una carga de absorber potencia activa. Por esta razón, f.d.p = 1 en cargas puramente resistivas. , Als Leistungsfaktor (auch WirkleistungsfakAls Leistungsfaktor (auch Wirkleistungsfaktor) wird in der elektrischen Wechselstromtechnik das Verhältnis vom Betrag der Wirkleistung zur Scheinleistung bezeichnet. Das Verhältnis wird in folgender Formel ausgedrückt: Der Leistungsfaktor kann zwischen 0 und 1 liegen:stungsfaktor kann zwischen 0 und 1 liegen: , 功率因数(英語:power factor,縮寫:PF)又称功率因子,是交流電力系統中功率因数(英語:power factor,縮寫:PF)又称功率因子,是交流電力系統中特有的物理量,是一負載所消耗的与其视在功率的比值,是0到1之間的無因次量。 有功功率代表一電路在特定時間作功的能力,视在功率是電壓和電流有效值的乘積。純電阻負載的视在功率等於有功功率,其功率因數為1。若負載是由電感、電容及電阻組成的線性負載,能量可能會在負載端及電源端往復流動,使得有功功率下降。若負載中有電感、電容及電阻以外的元件(非線性負載),會使得輸入電流的波形扭曲,也會使视在功率大於有功功率,這二種情形對應的功率因数會小於1。功率因数在一定程度上反映了发电机容量得以利用的比例,是合理用电的重要指标。 電力系統中,若一負載的功率因數較低,負載要產生相同功率輸出時所需要的電流就會提高。當電流提高時,電路系統的能量損失就會增加,而且電線及相關電力設備的容量也隨之增加。電力公司為了反映較大容量設備及浪費能量的成本,一般會對功率因數較低的工商業用戶以較高的電費費率來計算電費。 提高負載功率因數,使其接近1的技術稱為功率因數修正。低功率因數的線性負載(如感應馬達)可以藉由電感或電容組成的被動元件網路來提昇功因。非線性負載(如二極體)會使得輸入電流的波形扭曲,此情形可以由主動或被動的功率因數修正來抵消電流扭曲的影響,並且改善功因。功率因數修正設備可以位在中央變電站、分佈在電力系統中,或是放在耗能設備的內部。功因。功率因數修正設備可以位在中央變電站、分佈在電力系統中,或是放在耗能設備的內部。 , Коэффицие́нт мо́щности — безразмерная физиКоэффицие́нт мо́щности — безразмерная физическая величина, характеризующая потребителя переменного электрического тока с точки зрения наличия в нагрузке реактивной составляющей и мощности искажения (собирательное название — неактивная мощность). Следует отличать понятие «коэффициент мощности» от понятия «косинус фи», который равен косинусу сдвига фазы переменного тока, протекающего через нагрузку, относительно приложенного к ней напряжения. Второе понятие используют в случае синусоидальных тока и напряжения, и только в этом случае оба понятия эквивалентны.ко в этом случае оба понятия эквивалентны. , Účiník je kosinus vzájemného fázového posuÚčiník je kosinus vzájemného fázového posuvu mezi proudem a napětím elektrického obvodu s harmonickými průběhy střídavých proudů a napětí či periodickými průběhy o jednotlivých harmonických složkách proudů a napětí. Účiník je poměrem činného a zdánlivého elektrického výkonu v obvodu střídavého proudu a napětí, vyjadřuje, jak velkou část zdánlivého výkonu přeměňuje obvod na činný výkon, tj. na součet užitečného výkonu a ztrát. Značka: Jednotka SI: -ého výkonu a ztrát. Značka: Jednotka SI: - , In ingegneria elettrica, il fattore di potIn ingegneria elettrica, il fattore di potenza di un sistema elettrico a corrente alternata è il rapporto fra il modulo del vettore potenza attiva che alimenta un carico elettrico e il modulo del vettore potenza apparente che fluisce nel circuito. In un sistema con carichi lineari coincide con il coseno dell'angolo di sfasamento compreso tra i vettori tensione e corrente. È un numero adimensionale nell'intervallo chiuso tra -1 e 1. In quasi tutti i circuiti reali, la corrente è in ritardo rispetto alla tensione e la potenza apparente risulta quasi sempre maggiore della potenza attiva.uasi sempre maggiore della potenza attiva. , In electrical engineering, the power factoIn electrical engineering, the power factor of an AC power system is defined as the ratio of the real power absorbed by the load to the apparent power flowing in the circuit. Real power is the average of the instantaneous product of voltage and current and represents the capacity of the electricity for performing work. Apparent power is the product of RMS current and voltage. Due to energy stored in the load and returned to the source, or due to a non-linear load that distorts the wave shape of the current drawn from the source, the apparent power may be greater than the real power, so more current flows in the circuit than would be required to transfer real power alone. A power factor magnitude of less than one indicates the voltage and current are not in phase, reducing the average produe not in phase, reducing the average produ , 전기에는 직류와 교류가 존재하는데, 역률(영어: power factor)은 전기에는 직류와 교류가 존재하는데, 역률(영어: power factor)은 교류와 관계된다. 왜냐하면, 직류에서는 전압과 전류의 곱으로 전력이 되는데, 그 공식은 아래와 같이 나타낼 수 있다. P = 전력, V = 전압, I = 전류 직류에서는 위상이라는 개념이 없다. 하지만, 교류에서는 위상이 존재하며, 교류회로에서 역률은 (Active Power [단위 : W])과 (Apparent Power [단위 : VA])의 비를 말하는데, 이를 간단히 풀어서 해석하면, “전기설비에 걸리는 전압과 전류가 얼마나 효율적으로 일을 잘 하고 있는가?”로 나타내는 지표로도 활용된다. 역률은 유효전력을 피상전력(외관상의 전력)으로 나눈값이며, 교류 회로에서 전류와 전압의 위상차를 코사인 값(cosθ)으로 나타낸다. 직류에서는 전압과 전류만 곱하면 그것이 전력이었으나, 교류는 전압과 전류의 실효값을 곱한 피상전력이라는 것에 역률을 곱하여야 비로소 전력이 된다. 왜냐하면 직류처럼 일정한 흐름이 아닌, 정현파의 형태를 그리며 계속 지속적으로 변하기 때문이다. 즉, 직류처럼 일정한 값이 아닌, 계속 지속적으로 변하는 값이기 때문에 위상이 반드시 일치하지는 않는 것이다. (단, 위상각)변하는 값이기 때문에 위상이 반드시 일치하지는 않는 것이다. (단, 위상각) , Коефіціє́нт поту́жності — безрозмірна фізиКоефіціє́нт поту́жності — безрозмірна фізична величина, що означує споживача змінного електричного струму з точки зору наявності в навантаженні реактивної складової. Коефіцієнт потужності показує, наскільки зсувається по фазі змінний струм, що протікає крізь навантаження, щодо прикладеної до нього напруги. Чисельно коефіцієнт потужності дорівнює косинусу цього фазового зсуву.ті дорівнює косинусу цього фазового зсуву.
rdfs:label Facteur de puissance , معامل القدرة , 역률 , Faktor daya listrik , 功率因数 , 力率 , Współczynnik mocy , Коэффициент мощности , Arbeidsfactor , Účiník , Power factor , Fator de potência , Faktoro de povumo , Factor de potència , Factor de potencia , Fattore di potenza , Коефіцієнт потужності , Leistungsfaktor
hide properties that link here 
http://dbpedia.org/resource/PF + http://dbpedia.org/ontology/wikiPageDisambiguates
http://dbpedia.org/resource/Power_factor_correction + , http://dbpedia.org/resource/Cos_Phi_Meter + , http://dbpedia.org/resource/Power-factor_correction + , http://dbpedia.org/resource/Active_PFC + , http://dbpedia.org/resource/Inductive_load + , http://dbpedia.org/resource/Distortion_power_factor + , http://dbpedia.org/resource/Passive_PFC + , http://dbpedia.org/resource/Capacitive_load + , http://dbpedia.org/resource/Eli_the_iceman + , http://dbpedia.org/resource/Power_Factor + , http://dbpedia.org/resource/Power_Factor_Correction_Unit + , http://dbpedia.org/resource/Active_power_factor_correction + , http://dbpedia.org/resource/Lagging_current + , http://dbpedia.org/resource/Lagging_load + , http://dbpedia.org/resource/Leading_current + , http://dbpedia.org/resource/Leading_load + , http://dbpedia.org/resource/Power_Factor_Correction + , http://dbpedia.org/resource/Displacement_power_factor + http://dbpedia.org/ontology/wikiPageRedirects
http://dbpedia.org/resource/Wind_turbine_design + , http://dbpedia.org/resource/Power_electronics + , http://dbpedia.org/resource/Compact_fluorescent_lamp + , http://dbpedia.org/resource/LED_lamp + , http://dbpedia.org/resource/Fluorescent_lamp + , http://dbpedia.org/resource/Grow_light + , http://dbpedia.org/resource/Electric_power_system + , http://dbpedia.org/resource/HVDC_Inter-Island + , http://dbpedia.org/resource/Film_capacitor + , http://dbpedia.org/resource/Wind_power + , http://dbpedia.org/resource/Electric_power_quality + , http://dbpedia.org/resource/Capacitive_power_supply + , http://dbpedia.org/resource/Scott-T_transformer + , http://dbpedia.org/resource/Leading_and_lagging_current + , http://dbpedia.org/resource/Voltage_optimisation + , http://dbpedia.org/resource/Electric_power_transmission + , http://dbpedia.org/resource/Three_Gorges_Dam + , http://dbpedia.org/resource/John_Ambrose_Fleming + , http://dbpedia.org/resource/Power_factor_correction + , http://dbpedia.org/resource/Loharinag_Pala_Hydropower_Project + , http://dbpedia.org/resource/Switched-mode_power_supply + , http://dbpedia.org/resource/Wife_acceptance_factor + , http://dbpedia.org/resource/Energy_demand_management + , http://dbpedia.org/resource/FS_Class_E.470 + , http://dbpedia.org/resource/Current_transformer + , http://dbpedia.org/resource/Watt + , http://dbpedia.org/resource/Outline_of_electronics + , http://dbpedia.org/resource/Performance_and_modelling_of_AC_transmission + , http://dbpedia.org/resource/PF + , http://dbpedia.org/resource/Electricity_billing_in_the_UK + , http://dbpedia.org/resource/Flexible_AC_transmission_system + , http://dbpedia.org/resource/Synchronous_motor + , http://dbpedia.org/resource/Induction_motor + , http://dbpedia.org/resource/AC_motor + , http://dbpedia.org/resource/Incandescent_light_bulb + , http://dbpedia.org/resource/Glossary_of_engineering:_M%E2%80%93Z + , http://dbpedia.org/resource/Glossary_of_fuel_cell_terms + , http://dbpedia.org/resource/Outline_of_energy + , http://dbpedia.org/resource/List_of_dimensionless_quantities + , http://dbpedia.org/resource/Glossary_of_civil_engineering + , http://dbpedia.org/resource/Low_frequency_electromagnetic_compatibility + , http://dbpedia.org/resource/Electricity_meter + , http://dbpedia.org/resource/West_Burton_power_stations + , http://dbpedia.org/resource/Wreck_Cove_Hydroelectric_System + , http://dbpedia.org/resource/Dynamic_demand_%28electric_power%29 + , http://dbpedia.org/resource/Direct_torque_control + , http://dbpedia.org/resource/Zobel_network + , http://dbpedia.org/resource/Antenna_%28radio%29 + , http://dbpedia.org/resource/Register-transfer_level + , http://dbpedia.org/resource/Central_Organisation_for_Railway_Electrification + , http://dbpedia.org/resource/Solar_power_in_India + , http://dbpedia.org/resource/Grid_code + , http://dbpedia.org/resource/Index_of_electrical_engineering_articles + , http://dbpedia.org/resource/Glossary_of_electrical_and_electronics_engineering + , http://dbpedia.org/resource/Static_synchronous_compensator + , http://dbpedia.org/resource/Leakage_inductance + , http://dbpedia.org/resource/Polarity_%28mutual_inductance%29 + , http://dbpedia.org/resource/Synchronous_condenser + , http://dbpedia.org/resource/Single-wire_earth_return + , http://dbpedia.org/resource/K%C3%A1lm%C3%A1n_Kand%C3%B3 + , http://dbpedia.org/resource/Energy_storage_as_a_service + , http://dbpedia.org/resource/Liquid_rheostat + , http://dbpedia.org/resource/Glow_switch_starter + , http://dbpedia.org/resource/Kilowatt-hour + , http://dbpedia.org/resource/Electrical_measurements + , http://dbpedia.org/resource/UNIVAC_1105 + , http://dbpedia.org/resource/Dielectric_barrier_discharge + , http://dbpedia.org/resource/IEC_61000-3-2 + , http://dbpedia.org/resource/Cos_Phi_Meter + , http://dbpedia.org/resource/AC_power + , http://dbpedia.org/resource/Variable-frequency_drive + , http://dbpedia.org/resource/Green_computing + , http://dbpedia.org/resource/Capability_curve + , http://dbpedia.org/resource/Warsaw_rectifier + , http://dbpedia.org/resource/Electric_power + , http://dbpedia.org/resource/Electrical_substation + , http://dbpedia.org/resource/Electric_motor + , http://dbpedia.org/resource/Magnetic_core + , http://dbpedia.org/resource/Electric_power_distribution + , http://dbpedia.org/resource/Load_bank + , http://dbpedia.org/resource/Hydrargyrum_medium-arc_iodide_lamp + , http://dbpedia.org/resource/Smith%E2%80%93Putnam_wind_turbine + , http://dbpedia.org/resource/Power-voltage_curve + , http://dbpedia.org/resource/Electrical_characteristics_of_dynamic_loudspeakers + , http://dbpedia.org/resource/APFC + , http://dbpedia.org/resource/Electrical_ballast + , http://dbpedia.org/resource/Real_versus_nominal_value + , http://dbpedia.org/resource/Electrical_grid + , http://dbpedia.org/resource/Volt-ampere + , http://dbpedia.org/resource/Wattmeter + , http://dbpedia.org/resource/80_Plus + , http://dbpedia.org/resource/Active_rectification + , http://dbpedia.org/resource/Static_VAR_compensator + , http://dbpedia.org/resource/Islanding + , http://dbpedia.org/resource/V_curve + , http://dbpedia.org/resource/Open-circuit_test + , http://dbpedia.org/resource/Grid-tie_inverter + , http://dbpedia.org/resource/Blocked_rotor_test + , http://dbpedia.org/resource/Three-phase_electric_power + , http://dbpedia.org/resource/Power_supply + , http://dbpedia.org/resource/Amtrak%27s_25_Hz_traction_power_system + , http://dbpedia.org/resource/Light_switch + , http://dbpedia.org/resource/1977_IPSC_Handgun_World_Shoot + , http://dbpedia.org/resource/Motor_control_center + , http://dbpedia.org/resource/Rotary_phase_converter + , http://dbpedia.org/resource/Harmonics_%28electrical_power%29 + , http://dbpedia.org/resource/Power_conditioner + , http://dbpedia.org/resource/Dissipation_factor + , http://dbpedia.org/resource/Current_clamp + , http://dbpedia.org/resource/Kill_A_Watt + , http://dbpedia.org/resource/Capacitor_types + , http://dbpedia.org/resource/Transverter + , http://dbpedia.org/resource/Power-factor_correction + , http://dbpedia.org/resource/Active_PFC + , http://dbpedia.org/resource/Voltage_control_and_reactive_power_management + , http://dbpedia.org/resource/Inductive_load + , http://dbpedia.org/resource/Distortion_power_factor + , http://dbpedia.org/resource/Passive_PFC + , http://dbpedia.org/resource/Capacitive_load + , http://dbpedia.org/resource/Eli_the_iceman + , http://dbpedia.org/resource/Power_Factor + , http://dbpedia.org/resource/Power_Factor_Correction_Unit + , http://dbpedia.org/resource/Active_power_factor_correction + , http://dbpedia.org/resource/Lagging_current + , http://dbpedia.org/resource/Lagging_load + , http://dbpedia.org/resource/Leading_current + , http://dbpedia.org/resource/Leading_load + , http://dbpedia.org/resource/Power_Factor_Correction + , http://dbpedia.org/resource/Displacement_power_factor + , http://dbpedia.org/resource/Power_factor_correction_unit + http://dbpedia.org/ontology/wikiPageWikiLink
http://en.wikipedia.org/wiki/Power_factor + http://xmlns.com/foaf/0.1/primaryTopic
http://dbpedia.org/resource/Load_factor_%28electrical%29 + owl:differentFrom
http://dbpedia.org/resource/Power_factor + owl:sameAs
http://dbpedia.org/resource/Switched-mode_power_supply + , http://dbpedia.org/resource/Uninterruptible_power_supply + rdfs:seeAlso
 

 

Enter the name of the page to start semantic browsing from.